Design highlights:
1. Ergonomic key operation: silicone interactive backlit keyboard, trackball
2. Double screen display: 12.6 inch full-size multi-function touch screen +15.6 inch anti-glare LED screen
3. The machine can connect two probes at the same time
4. Synchronization ability:
B/CF, B/PDI or DPDI, B/PW, B/M, B+CF or PDI or DPDI/PW or M mode
5. Echo enhancement technology Adaptive signal processing technology was used to analyze the echo signal of the undetermined region through a unique intelligent data sensing method, which improved the image resolution and uniformity, and easily obtained high- definition heart images
6. Contrast imaging technology Using the second harmonic and nonlinear fundamental wave imaging, more accurate emission control to obtain excellent signal-to-noise ratio images. At the same time, it has microangiography imaging function and advanced angiographic quantitative analysis software, which provides more accurate judgment basis for clinical.
7. Elastography technology The latest elastography technology is used to improve the sensitivity of elastography, reduce the dependence on operation or manipulation, and show higher frame rate, better sensitivity, better stability and repeatability. 9, Harmonic imaging technology Using the second harmonics generated by the tissue boundary layer, THI significantly increases contrast resolution and improves image quality , especially for technically difficult subjects.
8.Composite imaging technology Allows the use of multiple scan space compartments, resulting in enhanced contrast and improved resolution visualization
Probe Specifications:
1. 2.0-10MHz V¬ariable frequency, frequency range 2.0-10MHz;
2. 5 kinds of frequencies of each probe, variable fundamental and harmonic frequency;
3. Abdomen: 2.5-6.0MHz;
4. Superficial:5.0-10MHz;
5. Cardiac:2.0-3.5MHz;
6. Puncture Guidance: probe puncture guide is optional, puncture line and Angle are adjustable;
7. Transvaginal: 5.0-9MHZ.
Optional Probes:
1. Abdominal probe: abdominal examination ( liver, gallbladder, pancreas, spleen, kidney, bladder, obstetric and adnexa uteri, etc.);
2. High frequency probe: thyroid, mammary gland, cervical artery, superficial blood vessels, nerve tissue, superficial muscle tissue, bone joint, etc.;
3.Micro-convex probe: infant abdominal examination (liver, gallbladder, pancreas, spleen, kidney, bladder, etc.);
4. Phased array probe: cardiac examination ( myocardial pulse, ejection fraction, cardiac function index, etc.);
5. Gynaecology probe (Transvaginal probe): uterine and uterine adnexa examination;
6. Visual artificial abortion probe: monitor surgical process in real time;
7. Rectal Probe: anorectal examination.
1. One-click optimization function
Improved image quality based on automatic structure detection
2. rich echo beamforming technology
The rich echo beam front allows the echo signal from adjacent beams that are traditionally ignored to be used to form a thinner, stronger imaging beam, providing better "out of focus" image resolution and deeper image penetration.
3. A maximum of 16 tasks for a transmission beam, resulting in excellent time resolution and higher frame rates.
4.Anatomical M-mode technology
Obtain accurate anatomical observations at any angle by freely placing sampling lines. Get better images with anatomical observation, up to three sampling lines
5.TDI: Tissue Doppler imaging allows you to quantitatively assess regional
myocardial motion and function, providing a complete TDI pattern for faster and more direct diagnosis.
Up to four frequencies in fundamental imaging
Up to two frequencies in Tissue harmonic imaging (probe dependent)
Dynamic range | 0-100% ,5% step |
SpeckleReduction | 8 levels(0-7) |
ScanDensity | H,M,L |
Gain | 0~100 % ,2% step |
TGC | eight TGC controls |
FrameAverage | 8 levels(0-7) |
LineAverage | 8 levels(0-7) |
Edge Enhance | 8 levels(0-7) |
Gray Maps | 15 types(0-14) |
Pseudocolor Maps | 7 types(0-6) |
Thermal Index | TIC,TIS,TIB |
2B, 4B formats | / |
Invert (U/D) and transposed (L/R) | / |
Focus Number | 4 |
Focus Depth | 16 levels(depth and probe dependent) |
FOV | 5 levels |
Image depth up to 35 cm in 0.5~4cm increments (depth dependent) | |
Phase inversion harmonic imaging technique is available for all probes |
Frequency | 2 levels |
Gain | 0~100% ,2% steps |
Wall filter | 8 levels(0-7) |
Sensitivity | H,M,L |
Flow | H,M,L |
Packet Size1 | 5 levels(0-4) |
FrameAverage | 8 levels(0-7) |
PostProc | 4 levels(0-3) |
Invert | On/Off |
Baseline | 7 levels(0-6) |
Color Maps | 4 levels(0-3) |
Color/PDI Width | 10%-100%, 10% |
Color/PDI Height | 0.5-30cm(probe dependent) |
Color/PDI Center Depth | 1-16cm(probe dependent) |
Steer | +/-12°,7°(linear probe) |
Frequency | 2 levels |
Gain | 0~100% ,2% steps |
Wall filter | 8 levels(0-7) |
Sensitivity | H,M,L |
Flow | H,M,L |
Packet Size1 | 5 levels(0-4) |
FrameAverage | 8 levels(0-7) |
PostProc | 4 levels(0-3) |
Invert | On/Off |
Baseline | 7 levels(0-6) |
PDI Maps | 2 levels(0-1) |
Color/PDI Width | 10%-100%, 10% |
Color/PDI Height | 0.5-30cm(probe dependent) |
Color/PDI Center Depth | 1-16cm(probe dependent) |
Steer | +/-12°, +/-7°(linear probe) |
Frequency | 2 levels |
Sweep speed | 5 levels(0-4) |
Scale | 16 levels(0-15) (depth and probe dependent) |
Scale Unit | cm/s,KHz |
Smooth | 8 levels(0-7) |
Pseudocolor Maps | 7 types(0-6) |
Dynamic range | 24-100, 2 step |
Gain | 0-100%, 2% step |
Wall filter | 4 levels(0-3) |
Dynamic range | 24-100, 2 step |
Gain | 0-100%, 2% step |
Wall filter | 4 levels(0-3) |
Angle correction | -89+89,1 step |
Gate size | 8 levels(0-7mm) |
Wall filter | 5 levels(0-4) |
Invert | On/Off |
Baseline | 7 levels |
Real-time auto Doppler trace: maximum velocity, mean velocity |
Frequency | Up to 3 fundamental and 2 harmonic imaging frequencies |
Edge enhance | 8 levels(0-7) |
Dynamic range | 0-100%,step 5% |
Gain | 0-100,step 2 |
Gray Maps | 15 levels(0-14) |
Pseudocolor Maps | 7 (0-6) |
Sweep speed | 5 levels(0-4) |
★user can press one key to save image parameters in screen
★user can press one key to restore image parameters to default status.
1.Quality Assureance
Strict quality control standards of ISO9001 to ensure the highest quality;
Respond to quality issues within 24 hours, and enjoy 7 days to return.
2.Warranty
All products have a 1 year warranty from our store.
3.Deliver time
Most Goods will be shipped within 72 hours after payment.
4.Three packagings to choose
You have special 3 gift box packaging options for each product.
5.Design Ability
Artwork/Instruction manual/product design according to customer’s requirement.
6.Customized LOGO and Packaging
1. Silk-screen printing logo(Min. order.200 pcs);
2. Laser engraved logo(Min. order.500 pcs);
3. Color box Package/polybag Package(Min. order.200 pcs).